Research Article
Vibration Isolation of Existing Buildings in Microvibration Traffic Environment
Table 2
Isolation difference between different floors of typical rooms.
| Isolation difference of each floor | Midspan | Wall-floor junction | Evaluation of isolation effects |
| Indoor room | 0.1 dB∼0.6 dB | 0.06 dB∼0.22 dB | The isolation level of each floor at the midspan differs greatly, and the difference is small at the junction | Kitchen (precast slab) | 0.1 dB∼0.9 dB | 0.03 dB∼0.17 dB | The isolation level of each floor at the midspan differs greatly, and the difference is small at the junction | Bathroom (cast-in-place slab) | 0.24 dB∼0.78 dB | 0.08 dB∼0.55 dB | The isolation level of each floor at the midspan differs greatly, and the difference is relatively large at the junction |
|
|