Research Article

Research on Pipeline Damage Imaging Technology Based on Ultrasonic Guided Waves

Table 7

Propagation distances between the reflection point and the signal receiving point.

NumberFirst signal time ()End echo signal time ()Damage signal time ()Calculated distance (mm)

S1109.101125.70370.65692.719
S2109.801125.80371.50693.515
S3109.201125.65372.90704.139
S4109.001125.65377.45729.370
S5109.251127.40384.85767.350
S6109.101125.70377.70730.167
S7109.201125.60373.10705.201
S8109.251125.80371.05694.047