Research Article

Dynamic Modeling and Parameters Optimization of Large Vibrating Screen with Full Degree of Freedom

Table 3

Comparison of FEM results with theoretical values.

Order123456

FEM results (Hz)1.97742.01663.61413.70234. 84866.2717
Theoretical values (Hz)1.99472.03463.58033.73004.60426.6498