Research Article

Absolute Instantaneous Optimal Control Performance Index for Active Vibration Control of Structures under Seismic Excitation

Table 3

Comparison measures for El Centro earthquake.

Story noNCLQRINS-ABS
P1P2P1P2P3 control energyP1P2P3 control energy

11.001.000.650.881 (14994 J)0.700.680.95 (14317 J)
21.951.551.261.011.290.82
32.821.961.821.271.830.99
43.572.262.331.432.291.20
54.192.382.761.682.681.41
64.662.483.111.852.971.59
74.982.673.331.913.181.72
85.142.803.451.923.281.78