Research Article

Robust Optimum Design of Multiple Tuned Mass Dampers for Vibration Control in Buildings Subjected to Seismic Excitation

Table 2

Robust design of MTMD.

RunPositions

Uncontrolled structure0.03941
1[0000000111]1313.857; 915.187; 1468.91443.358; 200.407; 11.0580.01588
2[0000000111]1439.044; 914.560; 1426.38743.400; 205.440; 11.3140.01595