Research Article
Detection of Inception Cavitation in Centrifugal Pump by Fluid-Borne Noise Diagnostic
Table 5
Incipient cavitation coefficient based on liquid-borne noise, airborne noise, and solid-borne vibration.
| Flow coefficient φ | 0.032 | 0.065 | 0.098 | Incipient cavitation coefficient based on liquid-borne noise σio | 0.282 | 0.318 | 0.357 | Incipient cavitation coefficient based on airborne noise σeo | 0.275 | 0.310 | 0.350 | Incipient cavitation coefficient based on solid-borne vibration σso1 at M1 | 0.276 | 0.310 | 0.341 | Incipient cavitation coefficient based on solid-borne vibration σso2 at M2 | 0.281 | 0.311 | 0.339 | Incipient cavitation coefficient based on solid-borne vibration σso3 at M3 | 0.280 | 0.312 | 0.348 | Incipient cavitation coefficient based on solid-borne vibration σso4 at M4 | 0.282 | 0.311 | 0.339 | Incipient cavitation coefficient based on solid-borne vibration σso5 at M5 | 0.282 | 0.312 | 0.345 |
|
|