Table 5

Incipient cavitation coefficient based on liquid-borne noise, airborne noise, and solid-borne vibration.

Flow coefficient φ0.0320.0650.098
Incipient cavitation coefficient based on liquid-borne noise σio0.2820.3180.357
Incipient cavitation coefficient based on airborne noise σeo0.2750.3100.350
Incipient cavitation coefficient based on solid-borne vibration σso1 at M10.2760.3100.341
Incipient cavitation coefficient based on solid-borne vibration σso2 at M20.2810.3110.339
Incipient cavitation coefficient based on solid-borne vibration σso3 at M30.2800.3120.348
Incipient cavitation coefficient based on solid-borne vibration σso4 at M40.2820.3110.339
Incipient cavitation coefficient based on solid-borne vibration σso5 at M50.2820.3120.345