Research Article

Detection of Inception Cavitation in Centrifugal Pump by Fluid-Borne Noise Diagnostic

Table 8

Critical cavitation coefficients based on the energy detection method.

Flow coefficient φ0.00560.01130.01410.01690.0225
Critical cavitation coefficient σc0.0170.0180.0200.0210.026