Tab 8
/
Research Article
Detection of Inception Cavitation in Centrifugal Pump by Fluid-Borne Noise Diagnostic
Table 8
Critical cavitation coefficients based on the energy detection method.
Flow coefficient
φ
0.0056
0.0113
0.0141
0.0169
0.0225
Critical cavitation coefficient
σ
c
0.017
0.018
0.020
0.021
0.026