Research Article
Detection of Inception Cavitation in Centrifugal Pump by Fluid-Borne Noise Diagnostic
Table 9
Incipient cavitation coefficients based on flow-borne noise at different flow coefficients.
| Flow coefficient φ | 0.0056 | 0.0113 | 0.0141 | 0.0169 | 0.0225 | Incipient cavitation coefficient based on OSPL σio | 0.022 | 0.025 | 0.028 | 0.031 | 0.033 | Incipient cavitation coefficient based on breadboard SPL σiob | 0.022 | — | 0.029 | — | 0.033 |
|
|