Comparison of moment at various loading levels between FEA and test results.

SpecimenDT1 (kN·m)DT2 (kN·m)DT3 (kN·m)
Load cycle (rotation)FEATestError (%)FEATestError (%)FEATestError (%)

1 (15 mrad)1051050127121514512912
2 (25 mrad)11095161411281015413514
3 (35 mrad)109981114013351521418
4 (45 mrad)109103613913901521455