Research Article
Modelling and Analysis of a Magnetorheological Damper with Nonmagnetized Passages in Piston and Minor Losses
Table 3
The parameters used in modelling the MR damper.
| Parameters | Values |
| | 3.9 × 10−4 | | 7 × 10−4 | | 2 × 10−4 | Lori. (m) | 0.017 | (kg/m3) | 2950 | Ar (m2) | 1.5394 × 10−4 | Ap (m2) | 1.7 × 10−3 | Anmp. (m2) | 3.1416 × 10−6 | Agap (m2) | 2.8965 × 10−5 | LMAX (mm) | 625 | LMIN (mm) | 453 | DP (mm) | 45.6 | | 0.03 | | 9.8 | | 0.7 | Aori. (m2) | 1.2032 × 10−4 | Lgap (m) | 0.0387 | c | 1.4 | at 2.5 amperes | 30 kPa | at 2 amperes | 27 kPa | at 1.6 amperes | 20 kPa | at 1 ampere | 12.5 kPa | at 0.6 ampere | 6.1 kPa | at 0 ampere | 1.2 kPa |
|
|