Research Article

Modelling and Analysis of a Magnetorheological Damper with Nonmagnetized Passages in Piston and Minor Losses

Table 4

Relative errors between the measured data and the simulated results at the current of 2 amperes.

Piston velocity (mm/s)ML&VL (%)VL (%)

50826.7
10012.957
3006.351
5000.929.1