Research Article

The Study of the Supernormal Mechanical Properties of Giant NPR Anchor Cables

Table 3

Deep Newton force monitoring warning level and warning criteria.

Warning levelCritical forecastFirst-level criterion: Newton force T (kN)Secondary criterion: Newton force increase ΔT (kN)

BlueStability warning0–20020–50 rise to yellow50–100 rise to orange>100 rise to red
YellowSubstability warning200–400Newton force rise (burst)
OrangeClose slip warning400–600Newton force rise (burst)
RedWarning time of the landslideMore than 600Sudden drop of Newton force

Note. Newton force T = TnT0; Newton force increase ΔT = TnTn-1; initial prestress T0 = 200 kN.