Research Article
The Study of the Supernormal Mechanical Properties of Giant NPR Anchor Cables
Table 3
Deep Newton force monitoring warning level and warning criteria.
| Warning level | Critical forecast | First-level criterion: Newton force T (kN) | Secondary criterion: Newton force increase ΔT (kN) |
| Blue | Stability warning | 0–200 | 20–50 rise to yellow | 50–100 rise to orange | >100 rise to red | Yellow | Substability warning | 200–400 | Newton force rise (burst) | Orange | Close slip warning | 400–600 | Newton force rise (burst) | Red | Warning time of the landslide | More than 600 | Sudden drop of Newton force |
|
|
Note. Newton force T = Tn−T0; Newton force increase ΔT = Tn−Tn-1; initial prestress T0 = 200 kN.
|