Research Article

Characterization and Evaluation of Rotation Accuracy of Hydrostatic Spindle under the Influence of Unbalance

Table 4

Average rotation accuracy of the spindle at different speeds.

Set speed (r/min)Measuring speed (r/min)Synchronization accuracy (μm)Asynchronous precision (μm)Synthetic precision (μm)

3003035.093.137.30
6006105.063.137.20
9009235.033.157.40
120012264.983.177.30