Research Article
Sealant Delamination Detection of Structural Sealant Glazing Systems Based on Driving-Point Accelerance
| Case | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
| Delamination severity (%) | 0 | 6.39 | 12.78 | 19.16 | 25.55 | 31.94 | 38.33 | 48.61 | 58.89 | Ea/% (driving point A) | 3.60 | 18.10 | 29.50 | 43.74 | 45.03 | 48.25 | 63.38 | 63.96 | 72.52 | Ea/% (driving point D) | 3.87 | 18.02 | 27.12 | 42.24 | 46.03 | 48.05 | 49.14 | 55.68 | 56.29 | Eω1/% | 0 | 0.13 | 0.79 | 1.67 | 2.64 | 2.69 | 6.94 | 18.13 | 20.33 | MAC | 1st order | 1 | 0.98 | 0.97 | 0.97 | 0.97 | 0.77 | 0.16 | 0.35 | 0.12 | 2nd order | 1 | 0.99 | 0.99 | 0.98 | 0.98 | 0.39 | 0.45 | 0.32 | 0.27 | 3rd order | 1 | 0.91 | 0.87 | 0.44 | 0.36 | 0.43 | 0.36 | 0.19 | 0.18 |
|
|