| Name of specimen | Presence of core slab | Type of expanded material | Set fall height H (mm) | Measurement impact velocity V (m/s) | Input energy Ek (J) |
| N-ST-H50 | Without core slab | ST | 50 | 0.99 | 9.77 | N-ST-H100 | | 100 | 1.40 | 19.7 | N-ST-H150 | | 150 | 1.74 | 30.3 | N-ST-H200 | | 200 | 1.98 | 39.1 | N-PP-H50 | PP | 50 | 0.97 | 9.34 | N-PP-H100 | | 100 | 1.40 | 19.7 | N-PP-H150 | | 150 | 1.74 | 30.3 | N-EST-H50 | EST | 50 | 0.97 | 9.34 | N-EST-H100 | | 100 | 1.40 | 19.7 | N-EST-H150 | | 150 | 1.81 | 32.9 | N-EST-H200 | | 200 | 1.98 | 39.1 | N-EST-H300 | | 300 | 2.56 | 65.5 |
| C-ST-H200 | With core slab | ST | 200 | 2.07 | 42.9 | C-ST-H300 | | 300 | 2.42 | 58.4 | C-ST-H400 | | 400 | 2.72 | 73.9 | C-PP-H200 | PP | 200 | 1.98 | 39.1 | C-PP-H300 | | 300 | 2.56 | 65.5 | C-EST-H200 | EST | 200 | 2.07 | 42.9 | C-EST-H300 | | 300 | 2.42 | 58.4 | C-EST-H400 | | 400 | 2.90 | 84.1 | C-EST-H500 | | 500 | 3.11 | 96.5 | C-EST-H600 | | 600 | 3.35 | 112.0 |
|
|