Abstract
Environmental vibration caused by traffic can affect the normal operation of precision instruments, and vibration-isolation measures should be taken to reduce such negative effects. The engineering background of this paper is a hard-X-ray tunnel under construction in Shanghai, China. First, field vibration measurements are used to study the characteristics of the ground traffic, maglev, subway, and other vibration sources near the tunnel, as well as the laws governing the propagation of vibration waves in the surface and soil layer. The finite-element modelling is then used to establish a two-dimensional numerical model for the field conditions, and the numerical results are compared with the field vibration measurements to validate the applicability of the numerical model for assessing the effects of environmental vibration. Finally, how the parameters of a pile-barrier vibration-isolation system, a vibration-isolation measure used widely for tunnels, influence its performance is studied. The results show the following: with increasing distance from the vibration source, the amplitude of the vibration acceleration decreases gradually, and the high-frequency part of the vibration wave is attenuated rapidly, whereas the low-frequency part is attenuated very little. The vibration-isolation effect of the pile barrier is directly proportional to the elastic modulus of the pile body, the pile length, and the hollow ratio of the pile, and inversely proportional to the stiffness of the filling material. The pile diameter, pile row number, and row spacing have little influence on the vibration-isolation effect. Increasing the pile diameter attenuates the acceleration amplitude somewhat around 10 Hz but has no effect on it around 5 Hz. Overall, the present numerical method is well suited to evaluating environmental vibration problems.
1. Introduction
With high-speed railways being constructed at a growing rate and speeds increasing on existing railways, vibrations due to traffic loads such as rail transit and high-speed trains are having increasing impacts on the surrounding environment. Vibrations due to traffic loads impact greatly the normal lives and work of residents, the structural safety of old buildings, and the production and use of precision instruments and equipment in factories and universities [1–4]. In particular, the effects of such vibrations on some precision instruments and equipment are to produce inaccurate readings, reduce accuracy, shorten service life, and even prevent normal operation. Therefore, vibrations due to traffic loads require urgent solutions as far as precision instruments and equipment are concerned. Examples include (i) the laboratories of the University of Washington Physics and Astronomy Building affected by light rail [5], (ii) medical buildings to be built above existing subways in Atlanta [6], and (iii) the influence of Beijing Metro Line 4 on precision equipment in the Physics Laboratory of Peking University [7]. Failure to treat vibrations due to traffic loads effectively will lead to immeasurable economic and scientific losses; therefore, it is very important to study the laws governing the propagation of vibration waves induced by traffic loads and propose vibration-reduction solutions.
There have been various previous studies of the characteristics of vibration waves induced by traffic loads and the main measures for alleviating the vibration intensity due to such loads [8–15]. Chen et al. [16] studied the response characteristics of train vibration acceleration in seasonal frozen soil near Daqing in China. Through vibration tests on a subway tunnel in Shanghai in China, Wei et al. [17] concluded that traffic loads mainly induce vertical vibrations. Schillemans [18] used a two-dimensional (2D) finite-element (FE) model to study railway vibration response and proposed vibration-reduction measures. Gardien et al. [19] analyzed the laws governing the propagation of subway vibrations in the Netherlands and studied how different model parameters influenced the calculation results. Liao et al. [20] studied the vibration-isolation effect of piles, found it to be related to the stiffness of piles, and concluded that the vibration-isolation effect of soft piles was better than that of hard piles.
Although the aforementioned research led to some meaningful conclusions, the previous studies generally involved only one vibration source and were focused mostly on the vibration responses of buildings above ground; there has been relatively little research on the vibration responses of underground tunnels with multiple vibration sources. Herein, the vibration-isolation performance of a pile barrier in an area of soft soil is studied based on a hard-X-ray free-electron laser facility under construction in Shanghai. The hard-X-ray tunnel is located in Zhangjiang Science City, which is adjacent to a maglev, metro line 16 (viaduct part), the Luoshan Road viaduct, and Luoshan Road. The vibrations in the surrounding environment are complex, and the aforementioned research results do not meet the needs of the project fully. Therefore, it is necessary to study vibration-isolation measures under the conditions of multiple vibration sources in a soft-soil area.
This paper begins with field vibration measurements being used to study the characteristics of the ground traffic, elevated road traffic, maglev, subway, and other vibration sources, as well as the laws governing the propagation of vibration waves in the surface and soil layer. Next, a numerical model of the field measurements is constructed, and its feasibility is assessed. Finally, a dynamic 2D numerical model of the maglev, Luoshan Road viaduct, Luoshan Road, and hard-X-ray tunnel is established to analyze how various parameters of the pile-barrier system influence its vibration-isolation effect.
2. Field Vibration Measurements
2.1. Problem Outline
The hard-X-ray free-electron laser facility is a major Chinese science and technology infrastructure project with the largest investment and longest construction period in China to date. The hard-X-ray tunnel is located in Zhangjiang Science City and has a buried depth of approximately 30 m and an outer diameter of 7 m. The main sources of vibration near the tunnel are a maglev, metro line 16, Luoshan Road viaduct traffic, and Luoshan Road ground traffic. Being sensitive equipment, the hard-X-ray free-electron laser equipment may be affected by environmental vibrations; therefore, it is necessary to study the characteristics of the ground traffic, maglev, subway, and other vibration sources and the laws governing the propagation of traffic vibration waves in the surface and soil layer.
2.2. Layout of Measuring Points and Measurement Instruments
Two groups of field vibration measurements were carried out. The first group is used to study the characteristics of the ground traffic, maglev, subway, and viaduct traffic near the hard-X-ray tunnel. The detailed locations of the measurement points are given in Table 1, and the site layout is shown in Figure 1. In the second group of field tests, the laws governing the propagation of vibration waves on the surface and in the soil layer are studied by monitoring the propagation of vibration waves induced by the maglev in the soil. The detailed locations of the test points are given in Table 2, and the layout of the field tests is shown in Figure 2. The 941 B high-sensitivity acceleration sensor manufactured by the Institute of Engineering Mechanics of the China Earthquake Administration was used in the field vibration measurements. Because the vibrations induced by traffic loads are mainly vertical vibrations [16, 17], this paper focuses on the vertical vibration acceleration due to traffic loads near the hard-X-ray tunnel.

(a)

(b)

(c)

(d)

2.3. Analysis of Field Measurement Results
2.3.1. Characteristics of Vibration Sources around Hard-X-Ray Tunnel
In this study, the SeismoSignal software was used to filter and eliminate trend terms from the field vibration measurement data. In the first group of field measurements, the vertical acceleration time histories of the maglev, metro line16 (viaduct part), Luoshan Road viaduct traffic, and Luoshan Road ground traffic were collected, and the frequency-domain information corresponding to the acceleration time histories was obtained by Fourier transform. The results are shown in Figures 3–6, and the comparison of the vibration acceleration data of the different vibration sources is summarized in Table 3. According to the calculation results, the vibration acceleration amplitudes of the maglev and metro line 16 are the largest, followed by that of the Luoshan Road viaduct traffic, with that of the Luoshan Road ground traffic being the smallest. The vibration acceleration amplitudes of the maglev, metro line 16 (viaduct part), and Luoshan Road viaduct traffic are concentrated mainly at medium and high frequencies, whereas that of the Luoshan Road ground traffic is concentrated mainly at low frequency.

(a)

(b)

(a)

(b)

(a)

(b)

(a)

(b)
2.3.2. Propagation and Attenuation Laws of Vibration Waves in Soil
The second group of field measurements measured the propagation and attenuation of vibration waves generated by the maglev in the soil. The distance between each measuring point and the maglev and the buried depth of each measuring point are given in Table 2, and the obtained acceleration time histories and their corresponding Fourier transform spectra are shown in Figures 7–14. Comparing the vibration time histories and frequency spectra of measurement points GII-5–GII 8 (see Figures 7–10) shows that (i) the amplitude of the vibration acceleration decreased gradually with increasing distance from the vibration source, (ii) the vibration wave was attenuated most obviously in the high-frequency part, and (iii) the attenuation in the low-frequency part was very small. For example, once the vibration wave had travelled 160 m, its part above 40 Hz had largely disappeared and it was basically concentrated below 30 Hz. Comparing the vibration time histories and frequency spectra of measurement points GII-1–GII 5 (see Figures 10–14) shows that the vibration acceleration decreased gradually with increasing depth. For example, once the vibration wave had reached a depth of 47 m, the vibration acceleration amplitude was only 20% of that at the surface.

(a)

(b)

(a)

(b)

(a)

(b)

(a)

(b)

(a)

(b)

(a)

(b)

(a)

(b)

(a)

(b)
3. Numerical Analysis
In this part of the study, finite-element (FE) simulation was used to investigate the second group of field measurements. The results of the numerical simulations are compared with the data obtained from the field measurements to verify the effectiveness of the numerical method in simulating environmental vibrations.
3.1. FE Calculation Model
The size of the FE numerical model and the arrangement of the measuring points were established in strict accordance with the actual conditions of the second group of field measurements. The FE model is shown in Figure 15. To meet the required calculation accuracy, the size of the FE model should be 1–1.5 times the shear wavelength of interest [21]. According to the field survey data, the maximum wave velocity in the soil layer is 375 m/s (see Table 4), and the field vibration measurements show that the acceleration amplitude is attenuated slowly at 5 Hz (see Figures 7–14), so the shear wavelength of interest is approximately 75 m. Combined with the actual site conditions, the size of the soil FE model was set as 600 m × 120 m.

3.2. Model Material Parameters
For vibrations due to traffic loads, the order of magnitude of the soil strain is generally 10−5 or less [22], in which case, the soil is in the elastic state [23] and so the elastic model is adopted in the soil model. The physical and mechanical parameters of the soil are selected according to the field survey data (see Table 4). The in situ shear wave velocities of the soil are measured by suspension logging technique during the site investigation and the dynamic shear modulus is calculated as follows [24]:where is the dynamic shear modulus; is the shear wave velocity of soil; and is the natural density of the soil, which is obtained from the in situ undisturbed soil through laboratory experiments.
The conversion relations between elastic modulus and shear modulus, shear wave velocity, and longitudinal wave velocity are as follows [25]:where is the dynamic elastic modulus; is Poisson’s ratio; and is the wave velocity of soil.
The calculation parameters of the maglev viaduct, the pile cap, and the pile foundation are as follows: elastic modulus E = 30,000 MPa; Poisson’s ratio ; density = 2500 kg/m3. In this study, the Rayleigh damping model was used in the 2D dynamic model, and the Rayleigh damping coefficients and are given bywhere is the damping ratio corresponding to frequency . To obtain the values of and , undisturbed soil was subjected to a resonant column test to obtain its damping ratio . The relationship between damping ratio and strain obtained from testing the dynamic characteristics of undisturbed soil is shown in Figure 16, from which it can be seen that when the vibration strain is 10−5, the soil damping ratio is 0.02. Because of the complexity of the damping ratio with frequency, it is assumed that the damping ratio is constant in a certain frequency range of interest. Figure 5 shows that the main vibration frequency band of the maglev is 10–70 Hz, so the values are taken as

The Rayleigh damping coefficients = 2.198 and = 7.96 × 10−5 are calculated by combining equations (3) and (4). When using the finite-element method to analyze the structure-ground dynamic interaction, an artificial boundary usually needs to be applied on the selected calculation area to simulate the radiation damping of the continuous medium, so that the scattered wave does not reflect when passing through the artificial boundary from the inside of the finite calculation area. The artificial boundary of the finite-element model in this paper can be equivalent to a parallel spring-damper system in which the spring stiffness and damping coefficient can be expressed as follows [26]:
Normal boundary:
Tangential boundary:where and are the normal and tangential spring stiffness, respectively; and are the normal and tangential damping coefficients of the damper, respectively; R is the distance from the wave source to the artificial boundary point; and and are artificial boundary parameters. As suggested by Gu [27], the recommended values of and are 1.33 and 0.67, respectively. It should be noted in equations (5) and (6) that the parameter R is expressed by the shortest distance from the vibration source to the artificial boundary. However, in actual problems, the scattering source is not a point source, but line source or area source with spatial distribution. Therefore, the determined spring stiffness in equations (5) and (6) is generally larger.
3.3. Analysis of Results
To verify the correctness of the numerical calculations, the numerical results are compared with the field measurement data in terms of the vibration displacements and the time histories and frequency spectra of the vibration accelerations. These comparisons are shown in Figures 17–25.

(a)

(b)

(a)

(b)

(a)

(b)

(a)

(b)

(a)

(b)

(a)

(b)

(a)

(b)

(a)

(b)

(a)

(b)
Figures 17(a)–24(a) show that the calculated acceleration time histories of GII-7 and GII-8 agree well with the measured field data. However, the calculated acceleration time history of the measuring point far away from the vibration source (e.g., GII-3 and GII-4) is consistent with the measured field data only in the part in which the acceleration amplitude is concentrated; this fact may be related to there being vibration sources other than the maglev in the field measurements.
Figures 17(b)–24(b) show that the calculated acceleration frequency spectrum at each measurement point is basically consistent with the field test data. The calculation results of GII-7 and GII-8 near the vibration source differ considerably from the field measurement data in the low-frequency part; this difference may be related to the fact that R waves are not attenuated on the surface when the latter is acted on by a linear vibration source. The calculated acceleration frequencies of the measuring point far away from the vibration source (e.g., GII-3 and GII-4) are smaller than the field vibration test data; again, this difference may be related to there being vibration sources other than the maglev in the field measurements.
Figure 25(a) shows that the numerically calculated maximum and root mean square (RMS) displacements within 100 m from the vibration source are slightly larger than the field measured data; again, this difference may be related to the fact that R waves are not attenuated on the surface when the latter is acted on by a linear vibration source. However, when the distance from the vibration source exceeds 100 m, the numerically calculated maximum and RMS displacements are close to the field measurement results. Generally speaking, the numerically calculated maximum and RMS displacements of the ground measurement points (GII-5-GII-8) are consistent with the attenuation trend of the field measurement data: with increasing distance from the vibration source, maximum and RMS displacements both decrease gradually.
Figure 25(b) shows that when the depth of the measuring point is less than 35 m, the numerically calculated maximum and RMS displacements are not consistent with the field measured data. However, when that depth exceeds 35 m, the numerically calculated results are relatively close to the field measured data. Generally speaking, the numerically calculated maximum and RMS displacements of the measuring points varying with depth (GII-1-GII-5) are consistent with the field measurement data regarding the attenuation trend: with increasing depth, maximum and RMS displacements both decrease gradually. The numerically calculated results show that the FE numerical method can simulate well the environmental vibration caused by traffic. The subsequent research reported herein analyzes the laws governing the influences of pile material, hollow ratio of the pile, filling material, pile length, pile diameter, and other parameters on the vibration isolation of the pile barrier based on the FE numerical method.
4. Analysis of Vibration-Isolation Performance of Pile Barrier
As a kind of passive isolation barrier system, pile-barrier vibration isolation can eliminate or prevent the adverse effects caused by vibration [28, 29]. This section reports on an extensive numerical parametric investigation of a pile-barrier vibration-isolation system with various pile materials, hollow ratio of the pile, filling materials, pile lengths, pile diameters, vibration-isolation positions, pile spacing, and row numbers to study how each parameter influences the vibration isolation of the pile barrier.
4.1. FE Calculation Model
A 2D model of the maglev, Luoshan Road viaduct, Luoshan Road, and hard-X-ray tunnel was established to study how the pile parameters influence the vibration-isolation effect. The FE model is shown in Figure 26. The outer diameter of the hard-X-ray tunnel model is 7 m, the inner diameter is 6.3 m, and the buried depth is 30 m. The inner and outer rings in the tunnel model are set as a lining layer and a grouting layer, respectively, and the monitoring point is located in the middle of the tunnel floor (see Figure 26). The calculation parameters of the structural model are given in Table 5. See Section 3 for the settings of the soil calculation parameters and FE model, which are not repeated here. The measured acceleration time-history data for the Luoshan Road traffic, Luoshan Road viaduct traffic, and maglev are filtered and used as the load for the numerical calculations, as shown in Figure 27. The calculations were performed first with no pile-barrier vibration-isolation measures in place, after which an extended numerical parametric analysis was performed to study how different pile materials, hollow ratio of the pile, filling materials, pile lengths, pile diameters, pile row numbers, and row spacing affect the vibration isolation of the pile barrier. Details of the parametric analysis are given in Table 6.


(a)

(b)

(c)
4.2. Calculation Results with No Pile Barrier Vibration Isolation
Figure 28 shows the vibration acceleration and displacement time histories and the acceleration frequency spectrum of the tunnel-floor monitoring point obtained from the numerical calculations with no vibration-isolation measures. The numerical calculations show that the maximum and RMS vibration displacements are 1086.64 and 280.95 nm, respectively. The frequency spectrum (see Figure 28(b)) shows that the vibration amplitude is concentrated mainly in the low-frequency part when it propagates to the bottom of the tunnel. Therefore, an effective way to reduce the tunnel vibration displacement is to block the vibration wave effectively in the low-frequency band.

(a)

(b)

(c)
4.3. Influence of Pile Material on Vibration Isolation Effect
In the FE simulation, concrete piles of different strength are set to study how the pile material influences the vibration-isolation performance of the pile barrier. The parameter selection of different pile materials and the calculated maximum and RMS vibration displacements of the monitoring point are shown in Group I of Table 6, and the frequency-spectrum comparison for different pile body materials and without vibration-isolation measures is shown in Figure 29. The calculation results show that the vibration-isolation effect is better with increasing pile stiffness when the other conditions remain unchanged. They also show that the vibration-isolation effect of foam plastic and foam concrete with a small elastic modulus is much poorer than that of concrete with a large elastic modulus, but the vibration-isolation effects of concrete piles of different strengths are mostly the same. The vibration-isolation measures adopted in engineering must consider comprehensively the vibration-isolation effect and cost. Therefore, if there is no strength requirement for the piles used for vibration isolation, it is recommended to choose row piles with C20 concrete.

(a)

(b)

(c)

(d)

(e)

(f)
4.4. Influence of Hollow Ratio (r) and Filling Material on Vibration Isolation Effect
Groups II and III of Table 6 investigate how the hollow ratio (r) of the pile and filling material influence the vibration-isolation effect. The calculated maximum and RMS vibration displacements of the monitoring points are shown in the same groups. The frequency-spectrum comparisons between different hollow ratios and filling materials and without vibration-isolation measures are shown in Figures 30 and 31, respectively. The calculation results show that with increasing hollow ratio of the pile, the vibration-isolation capacity improves. For example, the calculated maximum and RMS vibration displacements of piles with a hollow ratio of 0.39 are 48.96% and 34.36%, respectively, of those of solid piles. The calculation results also show that with increasing elastic modulus of the filler in the piles, the vibration-isolation capacity decreases gradually.

(a)

(b)

(c)

(d)

(e)

(f)

(a)

(b)

(c)

(d)
4.5. Influence of Pile Length (L) and Pile Diameter (D) on Vibration Isolation Effect
Groups IV and V of Table 6 explore the effects of the pile length and diameter. The calculated maximum and RMS vibration displacements of the monitoring points are shown in the same groups. The frequency-spectrum comparison between different pile lengths and diameters and without vibration-isolation measures is shown in Figures 32 and 33, respectively. The calculation results show that the vibration-isolation capacity of the pile barrier increases with increasing pile length. For example, when the pile length is increased from 10 m to 40 m, the maximum and RMS vibration displacements are reduced by 11% and 15.7%, respectively. The calculation results also show that the pile diameter has little influence on the vibration-isolation effect of the piles. Figure 33 shows that increasing the pile diameter has little effect on the acceleration amplitude around 5 Hz but affects it somewhat around 10 Hz.

(a)

(b)

(c)

(d)

(e)

(f)

(a)

(b)

(c)

(d)

(e)

(f)
4.6. Influence of Distance from Hard-X-Ray Tunnel (d) on Vibration Isolation Effect
Group VI of Table 6 shows the effect of the distance from the hard-X-ray tunnel. The calculated maximum and RMS vibration displacements of the monitoring points are shown in the same group. The frequency-spectrum comparison between different distances from the hard-X-ray tunnel and without vibration-isolation measures is shown in Figure 34. According to the calculation results, the vibration-isolation effect of the piles is no better if the piles are closer to the tunnel. Therefore, the vibration-isolation position of the pile barrier in practical engineering should be considered according to the actual working conditions.

(a)

(b)

(c)

(d)

(e)

(f)
4.7. Influence of Pile Row Number (n) and Row Spacing (c) on Vibration Isolation Effect
Groups VII and VIII of Table 6 evaluate the influences of pile row number and row spacing. The frequency-spectrum comparisons between different pile row numbers and row spacing and without vibration-isolation measures are shown in Figures 35 and 36, respectively. The calculation results show that the vibration-isolation ability of the pile barrier improves gradually with increasing pile row number and decreasing row spacing, but generally speaking, the influences of pile row number and row spacing on the vibration-isolation effect are small.

(a)

(b)

(c)

(d)

(a)

(b)

(c)

(d)

(e)

(f)
5. Conclusions
Based on a hard-X-ray tunnel under construction in Shanghai, relevant research was conducted on the vibration-isolation performance of a pile barrier in an area of soft soil. The main conclusions are as follows.
The vibration waves generated by the maglev, metro line 16 (viaduct part), and Luoshan Road viaduct traffic are concentrated mainly at middle and high frequencies, while those generated by the Luoshan Road ground traffic are concentrated mainly at low frequency. With increasing propagation distance and depth, the acceleration amplitude of the vibration waves is attenuated gradually. The high-frequency part of the vibration waves is attenuated rapidly in the soil, while the low-frequency part is attenuated slowly.
The attenuation law of the vibration waves in the soil as calculated by the numerical method is consistent with the field vibration measurements, thereby verifying the effectiveness of the numerical method in simulating environmental vibrations.
The pile body material, pile length, hollow ratio, filling material, and vibration-isolation position are the main factors affecting the vibration-isolation effect of the pile barrier. The vibration-isolation capacity of the pile barrier is proportional to the pile length, elastic modulus, and hollow ratio, and it is inversely proportional to the stiffness of the filling material. The pile diameter, row number, and row spacing have little influence on the vibration-isolation effect of the row piles. Increasing the pile diameter attenuates the acceleration amplitude around 10 Hz to a certain extent but basically has no influence on the acceleration amplitude around 5 Hz. With decreasing row spacing and increasing pile row number, the vibration-isolation effect of the row piles is improved slightly.
Data Availability
The data used to support the findings of this study are available from the corresponding author upon request.
Conflicts of Interest
The authors declare that they have no conflicts of interest.
Acknowledgments
This study was supported by the Shanghai Municipal Science and Technology Major Project (grant nos. 2017SHZDZX02and 17DZ1203902).