Properties of the superstructure and isolation systems of base-isolated buildings.

Component of base-isolated buildingsParameterUnitValues/range of the parameter used in the study

SuperstructureMass of each floor, kg1,427,100
Base mass, kg1,427,100
Damping ratio, 0.02–0.08
Fundamental time period, s0.1, 0.2, 0.4, 0.6, and 0.8
Height of each story, Hm3.5

Base isolation systemN-Z systemIsolation time period, s2.5
Isolation damping ratio, 0.05–0.15
Normalized yield strength, 0.025–0.2
Yield displacement, cm2.5
LRBIsolation time period, s2, 2.5, 3, and 3.5
Isolation damping ratio, 0.025–0.25
PF systemFriction coefficient, 0.025–0.2
Yield displacement, cm0.025
FPSIsolation time period, s2, 2.5, 3, and 3.5
Friction coefficient, 0.025–0.25
Yield displacement, cm0.025
R-FBIIsolation time period, s2.5
Isolation damping ratio, 0.05–0.15
Friction coefficient, 0.025–0.2
Yield displacement, cm0.025