Research Article

Seismic Fragility Assessment of Base-Isolated Steel Water Storage Tank

Table 4

Limit states for fragility assessment of tank.

Response of interestSlightModerateExtensive

Convective displacement, xc (m)0.050.10.15
Bearing displacement, xb (m)0.0060.0120.018
Base shear force, Fb (kN)154575