Research Article
Damage Detection in Plates with the Use of Laser-Measured Mode Shapes
Table 1
List of numerical simulations along with the first five natural frequencies of the plate.
| Simulation | Specimen state | F1 | F2 | F3 | F4 | F5 |
| S#1–S#2 | Intact, T = 20 C | 14.93 | 70.97 | 92.76 | 228.32 | 259.24 | S#3 | Intact, T = 25 C | 14.91 | 70.84 | 92.60 | 227.92 | 258.78 | S#4 | Intact, T = 30 C | 14.88 | 70.72 | 92.43 | 227.51 | 258.32 | S#5 | Intact, T = 35 C | 14.85 | 70.59 | 92.27 | 227.10 | 257.85 | S#6 | Intact, T = 40 C | 14.83 | 70.47 | 92.10 | 226.70 | 257.39 | S#7 | Intact, T = 45 C | 14.80 | 70.34 | 91.94 | 226.29 | 256.92 | S#8 | Damage 1, 3 mm | 14.93 | 70.97 | 92.75 | 228.28 | 259.19 | S#9 | Damage 1, 5 mm | 14.94 | 70.97 | 92.73 | 228.22 | 259.11 | S#10 | Damage 1, 7.5 mm | 14.94 | 70.97 | 92.71 | 228.13 | 258.98 | S#11 | Damage 1, 10 mm | 14.95 | 70.98 | 92.65 | 227.96 | 258.73 | S#12 | Damage 2, 3 mm | 14.93 | 70.96 | 92.77 | 228.31 | 259.25 | S#13 | Damage 2, 5 mm | 14.92 | 70.94 | 92.77 | 228.28 | 259.26 | S#14 | Damage 2, 7.5 mm | 14.91 | 70.92 | 92.77 | 228.25 | 259.27 | S#15 | Damage 2, 10 mm | 14.88 | 70.87 | 92.77 | 228.18 | 259.30 |
|
|