Table 10
Positions of spring vibration isolators in model.
| | Spring vibration isolators | Original model | The model with an eccentricity of 5% | The model with an eccentricity of 10% | | X | Y | X | Y | X | Y |
| | 1 | 0 | 0 | 0 | 0 | 0 | 0 | | 2 | 0.48 | 0 | 0 | 0 | 0 | 0 | | 3 | 0.96 | 0 | 0.48 | 0 | 0.48 | 0 | | 4 | 1.44 | 0 | 0.96 | 0 | 0.96 | 0 | | 5 | 1.92 | 0 | 1.44 | 0 | 1.44 | 0 | | 6 | 2.4 | 0 | 1.92 | 0 | 1.92 | 0 | | 7 | 0 | 3.585 | 0 | 3.585 | 0 | 3.585 | | 8 | 0.48 | 3.585 | 0.48 | 3.585 | 0 | 3.585 | | 9 | 0.96 | 3.585 | 0.96 | 3.585 | 0.48 | 3.585 | | 10 | 1.44 | 3.585 | 1.44 | 3.585 | 0.96 | 3.585 | | 11 | 1.92 | 3.585 | 1.92 | 3.585 | 1.44 | 3.585 | | 12 | 2.4 | 3.585 | 2.4 | 3.585 | 1.92 | 3.585 | | 13 | 0 | 4.335 | 0 | 4.335 | 0 | 4.335 | | 14 | 0 | 5.085 | 0 | 5.085 | 0 | 5.085 | | 15 | 0 | 6.085 | 0 | 6.085 | 0 | 6.085 | | 16 | 0 | 7.085 | 0 | 7.085 | 0 | 7.085 | | 17 | 2.4 | 4.335 | 2.4 | 4.335 | 2.4 | 4.335 | | 18 | 2.4 | 5.085 | 2.4 | 5.085 | 2.4 | 5.085 | | 19 | 2.4 | 6.085 | 2.4 | 6.085 | 2.4 | 6.085 | | 20 | 2.4 | 7.085 | 2.4 | 7.085 | 2.4 | 7.085 | | Center of rigidity | 1.2 | — | 1.08 | — | 0.96 | — | | Center of mass | 1.2 | — | 1.2 | — | 1.2 | — | | Relative error | 0% | — | 5% | — | 10% | — |
|
|