Research Article

Vibration Test and Shock Absorption of Coal Crusher Chambers in Thermal Power Plants (II): Numerical Analysis

Table 7

Calculated vibration-isolation efficiencies.

Spring vibration isolatorsReaction force (kN)
Condition D1Condition D2Condition D3Condition D4

10.1210.0420.0030.013
20.1210.0390.0030.014
30.1200.0360.0030.015
40.0950.0320.0040.017
50.1180.0290.0050.018
60.1170.0250.0060.019
70.0430.0530.0130.017
80.0420.0490.0120.016
90.0410.0460.0110.015
100.0400.0430.0100.013
110.0390.0390.0090.012
120.0390.0360.0080.011
130.0260.0550.0150.022
140.0700.0570.0170.026
150.0430.0600.0200.032
160.0650.0630.0230.038
170.0890.0380.0100.015
180.0240.0400.0120.020
190.0470.0430.0150.026
200.0690.0460.0180.032
Total of the reaction force1.370.870.220.39
Disturbing force9922
Vibration-isolation efficiency87.09%