Research Article
Enhancing Vibration Reduction on Lightweight Lower Control Arm
Table 5
Correlation results of experimental and FEM baseline LCA: the comparison takes into account the frequency and the MAC for each mode.
| | Eigenmode baseline | Frequency FEM (Hz) | Frequency EXP (Hz) | Δ frequency (%) | Diag (MAC) |
| | 1 | 243 | 245.43 | −0.99 | 0.965 | | 2 | 279 | 275.69 | +1.20 | 0.982 | | 3 | 398 | 396.78 | +0.31 | 0.967 | | 4 | 666 | 654.62 | +1.74 | 0.863 | | 5 | 812 | 780.18 | +4.08 | 0.520 | | 6 | 933 | 855.55 | +9.05 | 0.366 | | 7 | — | 988.09 | — | — |
|
|