Research Article

Enhancing Vibration Reduction on Lightweight Lower Control Arm

Table 6

Correlation results of experimental and FEM hybrid LCA the comparison takes into account the frequency and the MAC for each mode.

Eigenmode hybridFrequency FEM (Hz)Frequency EXP (Hz)Δ frequency (%)Diag (MAC)

1253274.14−7.710.873
2300286.184.830.952
3424424.21−0.050.916
4678683.48−0.800.899
5787763.263.110.199
6952984.45−3.300.457