Research Article
Noise Reduction for Modal Parameter Identification of the Measured FRFs Using the Modal Peak-Based Hankel-SVD Method
Table 4
The extracted modal parameters.
| Mode | Modal frequency (Hz) (Point 1) | Modal frequency (Hz) (Point 40) | Frequency difference (Hz) | Damping factor (Point 1) | Damping factor (Point 40) | Damping factor difference (%) |
| 1 | 64.63889 | 64.58773 | 0.05116 | 0.001152 | 0.001335 | 15.87176 | 2 | 392.3132 | 393.5316 | 1.2184 | 0.00645 | 0.005472 | 15.16743 | 3 | 459.1516 | 459.0252 | 0.1264 | 0.000667 | 0.000651 | 2.477419 | 4 | 1015.351 | — | — | 0.00753 | — | — | 5 | 1125.492 | 1126.48 | 0.988 | 0.00459 | 0.007716 | 68.11871 | 6 | 1147.168 | 1148.179 | 1.011 | 0.003201 | 0.00217 | 32.22889 | 7 | 1252.44 | — | — | 0.005597 | — | — | 8 | 1419.851 | 1419.687 | 0.164 | 0.000415 | 0.000545 | 31.51598 | 9 | 2175.132 | — | — | 0.002125 | — | — | 10 | 2524.38 | 2523.689 | 0.691 | 0.000578 | 0.000676 | 16.9878 |
|
|