Research Article

Research on Damping Characteristics of Interconnected Hydropneumatic Suspension considering the Effects of Hose and Check Valve

Table 1

Simulation model parameters.

DescriptionNotationValueUnits

Piston diameter0.11M
Rod diameter0.09M
Gas pressure of accumulator in static balance9.25 × 106Pa
Gas volume of accumulator in static balance1.2 × 10−3m3
Gas polytropic index1.4
Hydraulic oil density870kg/m3
Flow area of orifice1.41 × 10−5m2
Flow area of check valve1.41 × 10−5m2
Flow coefficient of orifice0.7
Flow coefficient of check valve0.6
Diameter of the hose0.013m
Length of hose from left (right) accumulator to chamber I of left (right) suspension cylinder0.5m
Length of hose from left (right) accumulator to chamber III of right (left) suspension cylinder2.5m