Research Article
Multi-Factor Modeling Method of the Load Sharing Ratio under Moving Train Loads
Table 5
Test factor levels and calculation results.
| Test number | z1 | z2 | z1·z2 | z12 | z22 | A | B | R2 |
| 1 | 1 | 1 | 1 | 1 | 1 | 3.716 | 0.486 | 0.998 | 2 | 1 | −1 | −1 | 1 | 1 | 3.573 | 0.422 | 0.981 | 3 | −1 | 1 | −1 | 1 | 1 | 3.762 | 0.535 | 0.988 | 4 | −1 | −1 | 1 | 1 | 1 | 3.324 | 0.295 | 0.956 | 5 | 1.078 | 0 | 0 | 1.162 | 0 | 3.671 | 0.438 | 0.992 | 6 | −1.078 | 0 | 0 | 1.162 | 0 | 3.436 | 0.288 | 0.987 | 7 | 0 | 1.078 | 0 | 0 | 1.162 | 3.641 | 0.418 | 0.997 | 8 | 0 | −1.078 | 0 | 0 | 1.162 | 3.456 | 0.340 | 0.985 | 9 | 0 | 0 | 0 | 0 | 0 | 3.553 | 0.357 | 0.996 | 10 | 0 | 0 | 0 | 0 | 0 | 3.562 | 0.350 | 0.996 |
|
|