Research Article
Research on the Distribution Rule of Percussion Response Pulse Width in Coin-Tap Test
Table 4
Calculated values of tapping response pulse width at different positions in the defective area.
| | Pulse width (ms) |
| Serial number | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | (mm) | 8 | 6 | 4 | 2 | 0 | 2 | 4 | 6 | 8 | Defect 1 | | | 0.080 | 0.189 | 0.225 | 0.189 | 0.080 | | | Defect 2 | 0.349 | 0.620 | 0.814 | 0.930 | 0.969 | 0.930 | 0.814 | 0.620 | 0.349 | Defect 3 | 0.162 | 0.288 | 0.378 | 0.432 | 0.450 | 0.432 | 0.378 | 0.288 | 0.162 |
|
|