Research Article

Seismic Evaluation and Retrofit of Reinforced Concrete Buildings with Masonry Infills Based on Material Strain Limit Approach

Table 5

Comparison of different parameters for the full RC-infilled frame.

ParametersBefore retrofitAfter retrofitRemarks
Full RC-infilled frameFull RC-infilled frameFull RC-infilled frameFull RC-infilled frame
In X-axisIn Y-axisIn X-axisIn Y-axis

Ultimate capacity7056.10 kN7063.99 kN7887.47 kN8072.72 kNAfter retrofitting, 11.78% increases in X-axis and 14.27% increases in the Y-axis
Yield displacement60.48 mm60.42 mm66.33 mm68.5 mmAfter retrofitting, 9.67% increases in the X-axis and 13.37% increases in the Y-axis
Maximum displacement70 mm70 mm100 mm100 mmAfter retrofitting, 42.85% increases in X-axis and Y-axis
Ductility1.161.161.511.46After retrofitting, 30.17% increases in X-axis and 25.86% increases in the Y-axis
Ductility reduction factor1.151.151.421.38After retrofitting, 23.47% increases in X-axis and 20.00% increases in Y-axis
Overstrength factor10.1910.2011.3911.66After retrofitting, 11.77% increases in X-axis and 14.31% increases in the Y-axis
Time period0.32 s0.32 s0.31 s0.31 sAfter retrofitting, 3.125% decreases in X-axis and Y-axis
R-factor5.855.868.088.04After retrofitting, 38.11% increases in X-axis and 37.20% increases in the Y-axis