Research Article
Seismic Evaluation and Retrofit of Reinforced Concrete Buildings with Masonry Infills Based on Material Strain Limit Approach
Table 6
Comparison of different parameters for the open ground storey RC-infilled frame.
| Parameters | Before retrofit | After retrofit | Remarks | Open ground storey RC-infilled frame | Open ground storey RC-infilled frame | Open ground storey RC-infilled frame | Open ground storey RC-infilled frame | In X-axis | In Y-axis | In X-axis | In Y-axis |
| Ultimate capacity | 1505.98 kN | 1498.58 kN | 6241.19 kN | 6250.54 kN | After retrofitting, 314.42% increases in X-axis and 317.09% increases in the Y-axis | Yield displacement | 22.14 mm | 21.93 mm | 54.62 mm | 54.72 mm | After retrofitting, 146.70% increases in the X-axis and 149.52% increases in the Y-axis | Maximum displacement | 42 mm | 42 mm | 93.33 mm | 86.67 mm | After retrofitting, 122.21% increases in X-axis and 106.35% increases in the Y-axis | Ductility | 1.89 | 1.91 | 1.70 | 1.58 | After retrofitting, 10.05% decreases in X-axis and 17.27% decreases in the Y-axis | Ductility reduction factor | 1.67 | 1.68 | 1.55 | 1.47 | After retrofitting, 7.18% decreases in X-axis and 12.5% decreases in Y-axis | Overstrength factor | 2.17 | 2.16 | 9.01 | 9.02 | After retrofitting, 315.20% increases in X-axis and 317.59% increases in the Y-axis | Time period | 0.48 s | 0.48 s | 0.32 s | 0.32 s | After retrofitting, 33.33% decreases in X-axis and Y-axis | R-factor | 1.81 | 1.81 | 6.98 | 6.62 | After retrofitting, 285.63% increases in X-axis and 265.74% increases in the Y-axis |
|
|