Research Article

Seismic Evaluation and Retrofit of Reinforced Concrete Buildings with Masonry Infills Based on Material Strain Limit Approach

Table 6

Comparison of different parameters for the open ground storey RC-infilled frame.

ParametersBefore retrofitAfter retrofitRemarks
Open ground storey RC-infilled frameOpen ground storey RC-infilled frameOpen ground storey RC-infilled frameOpen ground storey RC-infilled frame
In X-axisIn Y-axisIn X-axisIn Y-axis

Ultimate capacity1505.98 kN1498.58 kN6241.19 kN6250.54 kNAfter retrofitting, 314.42% increases in X-axis and 317.09% increases in the Y-axis
Yield displacement22.14 mm21.93 mm54.62 mm54.72 mmAfter retrofitting, 146.70% increases in the X-axis and 149.52% increases in the Y-axis
Maximum displacement42 mm42 mm93.33 mm86.67 mmAfter retrofitting, 122.21% increases in X-axis and 106.35% increases in the Y-axis
Ductility1.891.911.701.58After retrofitting, 10.05% decreases in X-axis and 17.27% decreases in the Y-axis
Ductility reduction factor1.671.681.551.47After retrofitting, 7.18% decreases in X-axis and 12.5% decreases in Y-axis
Overstrength factor2.172.169.019.02After retrofitting, 315.20% increases in X-axis and 317.59% increases in the Y-axis
Time period0.48 s0.48 s0.32 s0.32 sAfter retrofitting, 33.33% decreases in X-axis and Y-axis
R-factor1.811.816.986.62After retrofitting, 285.63% increases in X-axis and 265.74% increases in the Y-axis