Identification results of synchronous vibration parameter based on test data.

Identification parametersResonance region 1Resonance region 2Standard errors of two methods
New methodReference [23] methodNew methodReference [23] method

Vibration amplitude (mm)0.97690.97631.03601.04060.0033
Excitation order4.10264.10392.03382.02770.0044
Resonance speed frequency (Hz)15.960615.960344.771344.77090.0004
Resonance frequency (Hz)63.842463.841289.542689.54180.0010
Initial phase (°)−7.29−7.06−0.58−0.150.35