Research Article

Coarse Particle Motion Characteristics in a Double-Stage Slurry Pump Considering Leakage Flow

Table 3

Grid independence test.

No.CellsH/H1η/η1p/p1

Nonleak case1130,3541.0001.0001.000
2164,6870.9760.9830.985
3191,1110.9690.9750.976
4229,4080.9650.9710.972

Leak case1484,3781.0001.0001.000
2621,3140.9650.9710.983
3722,6140.9660.9710.977
4819,2440.9650.9710.974