Effect of failure energy in NCP mode on different dam performance indicators.

Model nameD5D6D7D8
0.5123.3

Reservoir water levelHi (m)121.02121.02121.02121.02
Hi/H41111
Ultimate resistance(Umax)i (mm)57.0157.2557.459.62
(Umax)i/(Umax)40.9911.011.04
Maximum displacementLi (m)38.3383940.4
Li/L41.0111.031.06