Research Article

Mechanical Modification of Resin Capsules by Adding Steel Particles

Table 2

Mechanical parameters of the resin specimens.

Specimen IDMillistrain at peak stressPeak stress (MPa)Ave. stress (MPa)E (GPa)Ave. E (GPa)Strain 50Stress 50E50 (GPa)

R129.8626.4824.920.890.9211.7113.241.13
R225.1924.410.9710.8712.211.12
R326.2923.850.9111.9011.931.00

Strain50 refers to the strain value when the stress reaches 50% of the peak stress value. Stress50 refers to 50% of the peak stress.