Research Article
Compressive Test Characteristics and Constitutive Relationship of Wet Polypropylene Macrofiber-Reinforced Shotcrete
Table 4
Energy absorption at time of failure for three different shotcrete mixes (MPa).
| Specimen code | Dry shotcrete | Wet shotcrete | Wet polypropylene macrofiber shotcrete |
| 1 | 8.381 | 10.677 | 21.946 | 2 | 6.617 | 7.078 | 19.153 | 3 | 7.453 | 7.346 | 20.472 | 4 | 7.922 | 8.081 | 23.867 | 5 | 5.155 | 6.529 | 17.875 | 6 | 8.920 | 7.946 | 17.336 | Average | 7.408 | 7.943 | 20.108 |
|
|