Research Article

Optimal Three-Dimensional Sensor Placement for Cable-Stayed Bridge Based on Dynamic Adjustment of Attenuation Factor Gravitational Search Algorithm

Table 3

Calculation results based on response of cable-stayed bridge.

OrderDirectionNatural frequencyModal participation factorEffective modal massri in corresponding directionR in three directions

30x5.47423258.20.10616E + 080.56610.1781
2z0.76273035.30.92131E + 070.44770.3327
3y0.96312800.40.78423E + 070.38690.4643
9y1.63492587.10.66931E + 070.33020.5766
48z10.2952257.70.50972E + 070.24770.6621
6z1.26622215.50.49084E + 070.23850.7445
11x1.8105−1498.90.30582E + 070.16310.7958
16x2.6809−1498.90.22467E + 070.11980.8335
7y1.3117−1493.80.22314E + 070.11010.8709
27y4.98421355.00.18360E + 070.09060.9017
34x6.5904925.950.85739E + 060.04570.9161
8z1.5352−662.250.43858E + 060.02130.9235