Research Article
Optimal Three-Dimensional Sensor Placement for Cable-Stayed Bridge Based on Dynamic Adjustment of Attenuation Factor Gravitational Search Algorithm
Table 3
Calculation results based on response of cable-stayed bridge.
| Order | Direction | Natural frequency | Modal participation factor | Effective modal mass | ri in corresponding direction | R in three directions |
| 30 | x | 5.4742 | 3258.2 | 0.10616E + 08 | 0.5661 | 0.1781 | 2 | z | 0.7627 | 3035.3 | 0.92131E + 07 | 0.4477 | 0.3327 | 3 | y | 0.9631 | 2800.4 | 0.78423E + 07 | 0.3869 | 0.4643 | 9 | y | 1.6349 | 2587.1 | 0.66931E + 07 | 0.3302 | 0.5766 | 48 | z | 10.295 | 2257.7 | 0.50972E + 07 | 0.2477 | 0.6621 | 6 | z | 1.2662 | 2215.5 | 0.49084E + 07 | 0.2385 | 0.7445 | 11 | x | 1.8105 | −1498.9 | 0.30582E + 07 | 0.1631 | 0.7958 | 16 | x | 2.6809 | −1498.9 | 0.22467E + 07 | 0.1198 | 0.8335 | 7 | y | 1.3117 | −1493.8 | 0.22314E + 07 | 0.1101 | 0.8709 | 27 | y | 4.9842 | 1355.0 | 0.18360E + 07 | 0.0906 | 0.9017 | 34 | x | 6.5904 | 925.95 | 0.85739E + 06 | 0.0457 | 0.9161 | 8 | z | 1.5352 | −662.25 | 0.43858E + 06 | 0.0213 | 0.9235 |
|
|