Research Article

Study on Model of Penetration into Thick Metallic Targets with Finite Planar Sizes by Long Rods

Table 1

Penetration data for long rod penetration into thick metallic targets with finite planar sizes.

rt (mm)rd (mm)rt/rdRt (MPa)Dshi (mm)Dmax (mm)δ

19.103.89804.902556.8587.2593.670.0736
19.103.89804.902556.8588.4993.670.0585
25.403.89576.523036.7286.0086.590.0068
25.453.89746.533039.3086.3186.550.0028
51.103.894813.124211.4974.8672.16−0.0360
51.053.896913.104208.9270.9772.190.0173
77.453.895919.884337.5066.7670.810.0607
77.103.895919.794334.7169.7270.840.0161
77.253.895619.834335.9669.2570.830.0227
111.003.890628.534494.8870.7369.17−0.0221
304.803.924877.664623.3767.86

Notes: Rt is the theoretical penetration resistance calculation result in this paper; Dmax is the theoretical penetration depth calculation result in this paper; Dshi is the test result of penetration depth in [13]; and δ is the relative error of Dmax and Dshi.