Research Article

Optimization Design and Internal Flow Field Study of Open-Design Vortex Pump

Table 3

Boundary conditions.

LocationBoundary condition typesSettings

InletMass flow inlet101,325 Pa, turbulence intensity
OutletPressure outletEqual to the operating flow rate
WallNonslip wallSurface roughness 0.005 mm
ImpellersRotating1485 r/min
VoluteStationary0 r/min
Lateral cavityStationary0 r/min