Test arrangements and scheme.

Test serial numberABCDEfficiency η (%)H (m)

1111149.0630.58
2122248.9529.12
3133348.0625.92
4212350.5833.38
5223150.1633.04
6231247.6927.91
7313249.8034.85
8321349.8631.25
9332147.2029.52