Table 1

Geometric parameters of the MCDs.

Serial numberName of the parameterSymbol (unit)Value

1The inner radius of the profilea (mm)104
2The outside radius of the profileb (mm)162
3The thickness of the profilet (mm)0.5
4The amplitude of the profilec (mm)3.5
5The thickness of the hubh1 (mm)1.2
6The thickness of the flangeh2 (mm)1.2
7The radius of the transition filletr2 (mm)2
8The radius of the inner circler0 (mm)89
9The radius of the outer circler1 (mm)182
10The number of diaphragms in an assemblym (piece)15