Research Article
Nonlinear Vibration Analysis of Rotor considering Cogging and Harmonic Effects
Table 1
Comparison of unbalanced magnetic pull.
| Static eccentricity | 0% | 10% | 20% | 30% | 40% | 50% |
| FEM results | 0 | 3.34 × 105 | 6.92 × 105 | 1.15 × 106 | 1.76 × 106 | 2.65 × 106 | Analytical results (no harmonics and stator slots) | 0 | 3.04 × 105 | 6.40 × 105 | 1.05 × 106 | 1.60 × 106 | 2.40 × 106 | Errors | 0% | 8.98% | 7.51% | 8.70% | 9.09% | 9.43% | Analytical results (with harmonics) | 0 | 3.83 × 105 | 7.82 × 105 | 1.27 × 106 | 2.05 × 106 | 2.85 × 106 | Errors | 0% | 14.67% | 13.01% | 10.43% | 16.48% | 7.55% | Analytical results (with harmonics and stator slots) | 0 | 3.52 × 105 | 7.31 × 105 | 1.22 × 106 | 1.86 × 106 | 2.78 × 106 | Errors | 0% | 5.39% | 5.64% | 6.09% | 5.68% | 4.91% |
|
|