Research Article

Optimal Operation of a Single Unit with an Adjustable Blade in an Interbasin Water Transfer Pumping Station Based on Successive Approximation Discretization for Blade Angle

Table 1

Summary of optimal operation results under typical operating conditions.

Daily average head (m)Operation load (%)Target TWPQ (104m3)Successive approximation numberActual TWPQ (m3)MOC (RMB)UMOC (RMB·10−4m−3)

3.13100315.51315959225761.5281.534
2315959225761.5281.534
3315749325737.5981.513
105331.31331842327455.7182.737
2331865527432.8382.662
3331605827394.4282.611
110347.11347558030622.1788.107
2347462930529.687.864
3347363630480.2687.747

3.53100307.11307676326962.4687.633
2307351926915.2087.571
3307351826905.1987.539
105322.41322632228678.6888.890
2322655528660.3088.826
3322655528660.3088.826
110337.81338286531977.6694.528
2338286531977.6694.528
3338264431962.3794.489

4.13100293.51293693228693.2697.698
2293689128677.1597.645
3293684428658.2997.582
105308.21309225030704.3099.294
2308554130633.3299.280
3308417730601.3599.220

4.5390255.31255636525854.82101.139
2255479125810.26101.027

A% load refers to A% of the TWPQ of the single pump unit operating at a designed blade angle of 0° and rated speed of 150 r/min for 24 h under the daily average head.