Optimal Operation of a Single Unit with an Adjustable Blade in an Interbasin Water Transfer Pumping Station Based on Successive Approximation Discretization for Blade Angle

Table 4

Analysis table of optimal operation benefit under typical operation conditions.

Daily average head (m)Water pumping load (%)UMOC saving compared with the first time of optimization (%)Reduction of actual TWPQ meeting water pumping load (104m3)Total cost saving of water pumping (RMB)
Single unit, 60 daysSingle pumping station, 60 daysSingle unit, 60 daysSingle pumping station, 60 days

3.131000.02712.5937.781435.84307.4
1050.15214.1942.573677.411032.2
1100.40811.6634.998514.625543.8

3.531000.10719.4758.413436.210308.6
1050.071-1.40-4.191102.83308.4
1100.0411.333.98917.42752.2

4.131000.1190.531.582098.26294.6
1050.07448.44145.316177.018531

4.53900.1119.4428.332673.68020.8