Comparison of results obtained from laboratory samples and numerical modeling.
| Number | Cross-section dimensions (mm) | Height (mm) | Layers of CFRP | Critical load from the laboratory (kN) | Critical load from numerical modeling (kN) | Percentage error |
| 1 | 2 100 100 | 300 | 0 | 238.2 | 239.59 | 0.5 | 2 | 2 100 100 | 300 | 1 | 338 | 337.1 | 0.27 | 3 | 2 100 100 | 300 | 2 | 425 | 427.31 | 0.55 |
|
|