Research Article

Wet Modal Analyses of Various Length Coaxial Sump Pump Rotors with Acoustic-Solid Coupling

Table 8

Predicted first natural frequencies and measured [22] and predicted critical speeds for various rotor lengths from the wet mode analysis.

D (mm)Predicted first natural frequency f (Hz)Predicted first critical speed n (RPM)Measured first critical speed [22], n (RPM)

90048.26528783467
120029.19417412107
150019.48211581429
180014.3268501038
200011.753700862
24008.340498623
27006.711399505
30005.531330417