Research Article
Structure Optimization of Vibrating Feeder Based on Inertia Release
Table 3
Central composite design test point.
| | Serial number | Outside rib increment (m) | Inside rib increment (m) | Maximum stress value (MPa) | Maximum deformation (mm) |
| | 1 | 0.01550 | 0.01550 | 7.06 | 0.773 | | 2 | 0.00100 | 0.01550 | 7.54 | 0.791 | | 3 | 0.00825 | 0.01550 | 7.37 | 0.784 | | 4 | 0.03000 | 0.01550 | 6.89 | 0.742 | | 5 | 0.02275 | 0.01550 | 7.01 | 0.776 | | 6 | 0.01550 | 0.00100 | 7.66 | 0.813 | | 7 | 0.01550 | 0.00825 | 7.21 | 0.824 | | 8 | 0.01550 | 0.03000 | 6.46 | 0.744 | | 9 | 0.01550 | 0.02275 | 6.57 | 0.757 | | 10 | 0.00100 | 0.00100 | 9.67 | 0.846 | | 11 | 0.00825 | 0.00825 | 8.31 | 0.803 | | 12 | 0.03000 | 0.00100 | 8.49 | 0.815 | | 13 | 0.02275 | 0.00825 | 7.71 | 0.856 | | 14 | 0.00100 | 0.03000 | 7.26 | 0.740 | | 15 | 0.00825 | 0.02275 | 7.59 | 0.814 | | 16 | 0.03000 | 0.03000 | 5.79 | 0.784 | | 17 | 0.02275 | 0.02275 | 6.37 | 0.776 |
|
|