Research Article

Damage Index Analysis of Retaining Wall Structures Based on the Impulse Response Function and Virtual Impulse Response Function

Table 7

The values of damage indexes of different points (the second time test at excitation point I).

PointsDamage indexCase 1Case 3Case 6Case 8

Point 1ersd00.03020.04660.0529
ERSD00.02160.03090.0352

Point 7ersd00.02240.02450.0294
ERSD00.03090.03430.0457

Point 12ersd00.55821.50442.4707
ERSD00.66701.83203.0664

Point 25ersd00.09620.14470.1824
ERSD00.10620.16020.1892