Perforation velocity comparison of SCS-250-6T with different conditions of tie bar for flat projectile.

ObjectDistance of tie bar (mm)Diameter of tie bar (mm)Yield strength of tie bar (MPa)Design value of tensile strength of tie bar (MPa)Perforation velocity (m/s)Deviation
FormulaFEM

SCS-250-6T150133453001521473.40%
7513345300160167−4.19%
5013345300173178−2.81%
75103453001541530.65%
7516345300169174−2.87%
75203453001801762.27%
7513307270157163−3.68%
7513400360164171−4.09%