Table 2
The flow rate and pressure rise of surge point under different clearances.
Volume flow rate (m
3
/min)
Pressure rise (kPa)
Clearance value (mm)
45.00
94.7
0.3
42.00
94.9
0.4
40.00
94.5
0.5
36.00
90.3
0.7
34.50
89.5
0.8
33.00
88