Research Article

Mitigation of Flow-Induced Vibration of Steel Catenary Risers with Pounding Tuned Mass Damper

Table 3

: Vibration control performance of the PTMD.

OCSCRDisplacementAcceleration
Response (m)Reduction ratio (%)Response (m/s2)Reduction ratio (%)

OC 1No control6.107.43
PTMD3.1448.523.6451.01

OC 2No control1.927.47
PTMD0.6873.813.8548.46

OC 3No control1.929.03
PTMD1.0943.225.8834.88

OC 4No control8.413.27
PTMD3.1162.986.3752.00

OC 5No control0.292.91
PTMD0.17440.002.2722.07