Research Article

Experimental Study on Lateral Resolution of Phased Array Ultrasonic Testing of Irregular Structure Weld Defects

Table 3

Comparison of testing depth and scanning angle between horizontal through holes 1 and 2.

Sectorial scanningSimulationTest

Max detection depthNO.1NO.2NO.1NO.2
37.66 mm32.83 mm37.12 mm32.29 mm
Scanning angleNO.1NO.2NO.1NO.2
47°51°48°51°